digitallasas.blogg.se

Antares vending machne evaporator replacement
Antares vending machne evaporator replacement






antares vending machne evaporator replacement
  1. #ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT INSTALL#
  2. #ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT FULL#
  3. #ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT PROFESSIONAL#

If you have input that can come closer to being an actual resolution, be my guest.

antares vending machne evaporator replacement

If you have no real addition to this post, stop slowing progress. The fact is, I am qualified and was looking to help this guy, sort of by breaking the ice. That is "silly." If a unit is thermostatically controlled, and the thermostat is operating appropriately, then 'low gas' would do nothing to freeze the product. If you had any slight ability in this field, you would have not even came close to posting the 'low gas' cause. If one is to say another's suggestion is wrong or silly they sure as hell better be telling why it is rather then snub their noses high in the air and climb on top of a soap box!Personally, who cares about your pet peeves? It was intended to be tongue in cheek, but you decided to start boosting the issue. Silly is posting "Just because I am a nice guy I will help you." all so comes of a smudge arrogant in my books too, why ells would one have to say such a thing other then to stroke their ego?Ī personal pet peeve is the type who dismiss some thing flat off with out explaining it, to me it says they do not understand why it is wrong and thus unqualified to say "Its silly". Silly? No just cautious, check every thing sequentially. He stated changes the therm setting to no resolve. As critical charge systems loose charge they go into deeper suction as load handling drops off, very cold evap, tends to freeze stuff in the box. Lets see, ran fine for 2 weeks, So the thermo was doing well other wise it would not have run well. And it has nothing to do with the accumulator or overcharging, these are critically charged systems that will not operate very long being low or high of refrigerant charge.Well some one has a rather inflated sense of self. The thermostat I listed has a constant cut-in at 39 degrees, set it in the middle, somewhere between 4-5 and let it be. Diet sodas freeze at a lower temperature than the regular soda, so keep that in mind. Depending on the thermostat stlye, you may have a coil sensing or an air sensing, and since I am not there looking at it, this will be the fix.

#ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT INSTALL#

Install a Ranco A12-1506 thermostat in the same manner as the original, except, put the 'pigtail' into the coil of the evaporator.

#ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT PROFESSIONAL#

You really should call a professional for this issue, but, disregard the leak thing, that is silly and should not have been posted. Just because I am a nice guy I will help you. What is the problem? It has a brand new compressor that was just installed.

antares vending machne evaporator replacement

I turned the thermostat setting down to about a "2". I'm totally freaked out that things are going to freeze again. I put a small (cheap) digital thermometer inside the machine and it read a 33 degree reading. I checked it several hours later and again everything was real cold. Exceeds DOEs AWEF requirement by up to 15 in the capacity range of 1/2 to 6 HP The Most Dynamic Condensing Unit and Unit Cooler Combination on the Market Leading-edge, AC powered variable speed technololgy. I bought a new thrermostat and changed it out and set the new thermostat on about a "3". I turned it down a quarter (to about a 3/4 setting.bewteen at 1/2 and a "1") and again it basically turned off (80 degrees). I turned it back up to a "1" setting and again it made the sodas very cold, almost freezing. I checked it the next day and it was warm (60-70 degrees). The thermostat was set at a "4" so I turned it all the way down to zero to warm it up. After setting it up it worked fine for about a week and then all it started freezing the sodas. We're here to help.I bought a refurbished Dixie Narco Coke machine (it is only 3-4 years old) about 2 weeks ago. If you need additional help finding the right part, our Customer Service Team is available at 88.

#ANTARES VENDING MACHNE EVAPORATOR REPLACEMENT FULL#

When you decide you need a part, enter the full model number of your Frigidaire appliance in the search bar to find the specific replacement part that matches your model. No matter the problem, Frigidaire Replacement Parts can get your machine up and running in no time. Is your washing machine leaking? Check the drain hose or inlet valve, then use our search feature to get the replacement. We also carry heating elements for dishwashers, so we've got you covered. Is your oven's heating element burned out? We offer both bake and broil elements to take care of that. If your refrigerator isn't working, you will find thermostats, baffles, gaskets, motors, fan blades, and much more here. When it comes time to repair your Frigidaire appliance, you can trust us to get you the right parts to fix your problem. No matter the product, you can rest assured that it will provide reliable service for years to come.

antares vending machne evaporator replacement

Frigidaire appliances are well-known for their quality, usability, and design.








Antares vending machne evaporator replacement